Ultrasonic commercial gas base meter G6–G25, 180 mm centre distance and G2″ connection. No display and no communication module — the metering core and its output interface only, supplied unbranded for your own type approval, display and nameplate. Ultrasonic, not a diaphragm meter. Aluminium or steel housing, pulse / encoder / RS485 or bare core output.
Base meters carry no N suffix — that letter marks the communication module. A base meter leaves the module to you, so the model ends at the size code (with W where the variant is the wider G-size body).
Datasheet, dimension drawing and test report available on request.
A proven commercial metering core spanning G6–G25. Your programme starts at your own certification, not at a blank sheet.
G6 through G25W on a single platform — one set of spares, one spare-parts list, one certification file.
180 mm centre distance and G2″ connection match the mechanical meters already installed in commercial premises.
Connection, output signal, housing and valve configuration set from your requirement and your market's rules.
Figures from our own datasheets and type-test reports. Ask for the datasheet for the complete dimension drawings.
| Size range | G6 / G10 / G10W / G16 / G25 / G25W |
|---|---|
| Accuracy class | Class 1.5 — OIML R137 |
| Body material | Aluminium or steel, per your specification |
| Protection class | IP65 |
| Output signal | Pulse, encoder, RS485 or bare core — taken from the meter to your own communication module or local display |
| Power supply | 3.6 V Li-SOCl2 battery, design life ≥ 15 years |
| Temperature & pressure compensation | Real-time — standard-volume metering |
| Operating temperature | -25 °C ~ 55 °C |
| Maximum working pressure | 30 kPa |
| Pressure loss | ≤ 200 Pa (G6) · ≤ 375 Pa (G10–G25) |
| Explosion protection | Ex ib IIB T3 Gb — certified by NEPSI, Shanghai (cert. GYB23.1913X) |
| Applicable gases | Natural gas (H / L / E), LPG, hydrogen-blended natural gas |
| Turndown ratio | R160 / R250 (by model) |
| Flow path | Labyrinth dust-proof design · no magnetic transmission parts, immune to external magnetic interference |
| Delivery form | Unbranded, with the marking and nameplate left to you |
Dimensions in mm. Values identical across the range are shown once, below the table. Request the dimension drawing for your model.
| Nominal Diameter | L | W | H | Centre-to-centre | Meter Thread |
|---|---|---|---|---|---|
| G6 – G25W | 437 mm | 279 mm | 225 mm | 180 mm | G2″ |
| Parameter | HGU-A6 | HGU-A10 | HGU-A10W | HGU-A25 | HGU-A25W |
|---|---|---|---|---|---|
| Size | G6 | G10 | G10W | G25 | G25W |
| Max flow Qmax | 10 m³/h | 16 m³/h | 16 m³/h | 40 m³/h | 40 m³/h |
| Min flow Qmin | 0.06 m³/h | 0.1 m³/h | 0.06 m³/h | 0.25 m³/h | 0.16 m³/h |
| Transitional flow Qt | 1.0 m³/h | 1.6 m³/h | 1.0 m³/h | 4.0 m³/h | 2.5 m³/h |
| Turndown ratio | R160 | R160 | R250 | R160 | R250 |
We build to your specification, not to a fixed catalogue item. Tell us the market and the certification route and we will quote the configuration.
Pulse, encoder, RS485 or bare core — whichever your read-out system or module expects.
Aluminium or steel, to suit the installation environment.
With or without the built-in shut-off valve, per your market's requirement.
Accuracy class and turndown configured to the market you are certifying for.
We ship unbranded; your nameplate, model code and packing are applied by you.
Technical documentation, test reports and sample units for your local type-approval process.
Not every customer wants our display or our radio. A base meter is the measuring core on its own: no display, no communication module, just the metering engine and the output interface — ready for your own electronics and your own nameplate.
It is the same ultrasonic metering core as our branded commercial meter, delivered unbranded. It is an ultrasonic meter, not a diaphragm meter — nothing moves, nothing wears, and the reading does not drift with age.
One platform spans G6 through G25W. That matters commercially: a single set of spares, a single spare-parts list and a single certification file instead of four, whether you are stocking meters or assembling your own.
A 180 mm centre distance and a G2″ connection place it directly in the footprint of the mechanical meters already installed in commercial kitchens, building boilers and light industrial sites.
You specify the output signal, housing material, valve configuration and flow range. That specification is what we build to, and it is what goes on your certificate.




Standard products, OEM base meters, or a complete metering solution — send us your specification and we will work from what you actually need.