G6–G25 ultrasonic gas meter for commercial kitchens, building boilers and light industry. 180 mm centre distance and G2″ connection — a drop-in replacement for mechanical meters. R160/R250 turndown, Class 1.5 to OIML R137, built-in safety shut-off valve.
Datasheet, dimension drawing and test report available on request.
Minimum flow down to 0.06 m³/h on G10W, so low night loads and peak commercial demand are both billed accurately.
No rotor, impeller or diaphragm to wear or age. Accuracy does not drift over service life.
Ex ib IIB T3 Gb, suitable for Zone 1 explosive gas atmospheres. Certified by NEPSI, Shanghai.
3.6 V Li-SOCl2 primary battery plus backup supply — metering and data stay online through battery change.
Figures from our own datasheets and type-test reports. Ask for the datasheet for the complete dimension drawings.
| Size range | G6 / G10 / G10W / G16 / G25 / G25W (gases G6–G25) |
|---|---|
| Accuracy class | Class 1.5 — OIML R137 |
| Body material | Aluminium |
| Protection class | IP65 |
| Communication | Two configurations. Remote reading: local display plus an NB-IoT / LoRaWAN / CAT1 module, so the meter can be read on site or from the office. Local reading: the same meter and the same local display, supplied without a communication module — read on site, with optional pulse output. Only the communication differs; the measuring core and the display do not. |
| Battery | 3.6 V Li-SOCl2 primary + backup · design life ≥ 15 years |
| Temperature & pressure compensation | Real-time — standard-volume metering |
| Operating temperature | -25 °C ~ 55 °C |
| Maximum working pressure | 30 kPa |
| Pressure loss | ≤ 200 Pa (G6) · ≤ 375 Pa (G10–G25) |
| Explosion protection | Ex ib IIB T3 Gb — certified by NEPSI, Shanghai (cert. GYB23.1913X) |
| Applicable gases | Natural gas (H / L / E), LPG, hydrogen-blended natural gas |
| Sampling rate | Adaptive high-frequency 0.5–8 Hz |
| Safety shut-off valve | Built in — automatic shut-off on abnormal high flow or leakage; remotely controllable |
| Self-diagnostics | Continuous health self-check · online speed-of-sound verification (air / natural-gas identification) |
| Interference resistance | Labyrinth dust-proof design · no magnetic transmission parts, immune to external magnetic interference |
| Event alarms | Reverse flow, high temperature, leakage, abnormal high flow, constant flow, meter removal |
| Optical interface | IEC 62056-21 |
| Firmware upgrade | Local via optical port, and remote OTA |
| Data logging | Hourly / daily / monthly + minute-level load (history ≥ 90 days) |
| Display | Local LCD — total volume, instantaneous flow, temperature, pressure. Fitted on both configurations. |
Dimensions in mm. Values identical across the range are shown once, below the table. Request the dimension drawing for your model.
| Nominal Diameter | L | W | H | Centre-to-centre | Meter Thread |
|---|---|---|---|---|---|
| G6 – G25W | 437 mm | 279 mm | 225 mm | 180 mm | G2″ |
| Parameter | HGU-A6N | HGU-A10N | HGU-A10WN | HGU-A25N | HGU-A25WN |
|---|---|---|---|---|---|
| Size | G6 | G10 | G10W | G25 | G25W |
| Max flow Qmax | 10 m³/h | 16 m³/h | 16 m³/h | 40 m³/h | 40 m³/h |
| Min flow Qmin | 0.06 m³/h | 0.1 m³/h | 0.06 m³/h | 0.25 m³/h | 0.16 m³/h |
| Transitional flow Qt | 1.0 m³/h | 1.6 m³/h | 1.0 m³/h | 4.0 m³/h | 2.5 m³/h |
| Turndown ratio | R160 | R160 | R250 | R160 | R250 |
We build to your specification, not to a fixed catalogue item. Tell us the market and the certification route and we will quote the configuration.
Two configurations: with a module (NB-IoT / LoRaWAN / CAT1) for remote reading, or without one for local reading with optional pulse output. Same meter, same accuracy — only the communication differs.
Pulse, encoder, RS485 or bare core, depending on your read-out system.
Aluminium or steel housing to suit the installation environment.
With or without the built-in shut-off valve, per your market's requirement.
Your nameplate, model code and language on the meter and the packing.
We supply the technical documentation and sample units your local test laboratory needs to type-approve the meter under your own brand.
The HGU-A commercial series covers G6 through G25 in a single platform, so you carry one set of spares and one spare-parts list instead of four.
A 180 mm centre distance and a G2″ connection make it a drop-in replacement for the mechanical meters already installed in commercial kitchens, building boilers and light industrial sites — no pipework modification required.
Measurement is by ultrasonic time-of-flight with real-time temperature and pressure compensation, so the volume you bill is standard volume rather than the volume at whatever temperature it happened to pass the meter.
The series is supplied in both communicating and local-reading versions, from the same production line and the same metering core.




Standard products, OEM base meters, or a complete metering solution — send us your specification and we will work from what you actually need.