G1.6–G4 residential ultrasonic gas meter, 130 mm centre distance and M30×2 connection. R160/R250/R400 turndown, Class 1.5 to OIML R137, built-in safety shut-off valve with high-flow and leakage alarms.
Datasheet, dimension drawing and test report available on request.
The standard residential footprint. Drops into the position of the mechanical meter already installed — no pipework change.
No diaphragm or gear train to age. Accuracy does not drift over the service life.
Automatic shut-off on abnormal high flow or leakage, remotely controllable. Alarms for reverse flow, high temperature and meter removal.
3.6 V Li-SOCl2 with a 15-year design life, plus ≥90 days of minute-level load data.
Figures from our own datasheets and type-test reports. Ask for the datasheet for the complete dimension drawings.
| Size range | G1.6 / G2.5 / G4 / G4W |
|---|---|
| Accuracy class | Class 1.5 — OIML R137 |
| Body material | Aluminium |
| Protection class | IP65 |
| Communication | Two configurations. Remote reading: local display plus an NB-IoT / LoRaWAN / CAT1 module, so the meter can be read on site or from the office. Local reading: the same meter and the same local display, supplied without a communication module — read on site, with optional pulse output. Only the communication differs; the measuring core and the display do not. |
| Battery | 3.6 V Li-SOCl2, design life ≥ 15 years |
| Temperature & pressure compensation | Real-time — standard-volume metering |
| Operating temperature | -25 °C ~ 55 °C |
| Maximum working pressure | 15 kPa |
| Pressure loss | < 200 Pa at Qmax |
| Explosion protection | Ex ib IIB T3 Gb — certified by NEPSI, Shanghai (cert. GYB23.2061X, valid to 2028-06) |
| Applicable gases | Natural gas (H / L / E), LPG, hydrogen-blended natural gas |
| Turndown ratio | R160 / R250 / R400 (by model) |
| Sampling rate | Adaptive high-frequency 0.5–8 Hz |
| Safety shut-off valve | Built in — automatic shut-off on abnormal high flow or leakage; remotely controllable |
| Self-diagnostics | Continuous health self-check · online speed-of-sound verification (air / natural-gas identification) |
| Interference resistance | Labyrinth dust-proof design · no magnetic transmission parts, immune to external magnetic interference |
| Event alarms | Reverse flow, high temperature, leakage, abnormal high flow, constant flow, meter removal / reinstallation |
| Optical interface | IEC 62056-21 |
| Firmware upgrade | Local via optical port, and remote OTA |
| Data logging | Hourly / daily / monthly + minute-level load (history ≥ 90 days) |
| Display | Local LCD — total volume, instantaneous flow, temperature, pressure. Fitted on both configurations. |
| Standards basis | Metering performance to GB/T 39841-2021 (Ultrasonic Gas Meters); explosion protection to GB/T 3836.1-2021 and GB/T 3836.4-2021 |
Dimensions in mm. Values identical across the range are shown once, below the table. Request the dimension drawing for your model.
| Nominal Diameter | L | W | H | Centre-to-centre | Meter Thread |
|---|---|---|---|---|---|
| G1.6 – G4W | 190 mm | 112 mm | 139 mm | 130 mm | M30×2 |
| Parameter | HGU-A1.6N | HGU-A2.5N | HGU-A4N | HGU-A4WN |
|---|---|---|---|---|
| Size | G1.6 | G2.5 | G4 | G4W |
| Max flow Qmax | 2.5 m³/h | 4 m³/h | 6 m³/h | 6 m³/h |
| Min flow Qmin | 0.016 m³/h | 0.025 m³/h | 0.04 m³/h | 0.016 m³/h |
| Transitional flow Qt | 0.25 m³/h | 0.4 m³/h | 0.6 m³/h | 0.25 m³/h |
| Turndown ratio | R160 | R160 | R160 | R400 |
We build to your specification, not to a fixed catalogue item. Tell us the market and the certification route and we will quote the configuration.
Two configurations: with a module (NB-IoT / LoRaWAN / CAT1) for remote reading, or without one for local reading with optional pulse output. Same meter, same accuracy — only the communication differs.
Pulse, encoder or bare core, depending on your read-out system.
Aluminium or steel housing to suit the installation environment.
With or without the built-in shut-off valve, per your market's requirement.
Your nameplate, model code and language on the meter and the packing.
We supply the technical documentation and sample units your local test laboratory needs to type-approve the meter under your own brand.
The residential series covers G1.6 through G4W from one platform. A 130 mm centre distance and an M30×2 connection place it directly in the position of the mechanical meter already installed in most households, so replacement does not mean re-piping.
Measurement is ultrasonic time-of-flight with real-time temperature and pressure compensation, so the volume you bill is standard volume rather than the volume at whatever temperature it happened to pass the meter.
A built-in safety valve shuts off automatically on abnormal high flow or leakage and can be operated remotely. The meter also raises alarms for reverse flow, high temperature, constant flow and removal from its mount.
Explosion protection was verified by the National Explosion-proof Electrical Products Quality Supervision and Inspection Centre (NEPSI, Shanghai) — certificate GYB23.2061X, marking Ex ib IIB T3 Gb, suitable for Zone 1 explosive gas atmospheres.




Standard products, OEM base meters, or a complete metering solution — send us your specification and we will work from what you actually need.