DN15–DN25 residential ultrasonic water meter with an all-polymer one-piece body — the measuring tube has no openings. R500/R800 range, IP68, U0/D0 any-position installation. 100% lead-free, no metal parts.
Datasheet, dimension drawing and test report available on request.
Minimum flow down to 3.125 L/h on DN15, and a starting flow of 1 L/h — even dripping consumption is measured.
One-piece polymer body with no openings in the measuring tube. No o-rings, no gaskets, no leak paths.
No straight pipe run required, and the meter can be mounted in any orientation. Fits where mechanical meters will not.
3.6 V lithium with a 15-year design life, plus ≥24 months of hourly, daily and monthly logging.
Figures from our own datasheets and type-test reports. Ask for the datasheet for the complete dimension drawings.
| Body material | Engineering polymer — 100% lead-free, no metal parts |
|---|---|
| Accuracy class | Class 2 — ISO 4064:2014 |
| Measurement range (Q3/Q1) | R500 / R800 |
| Starting flow | 1 L/h |
| Thermal class | T30 / T50 |
| Operating temperature | -25 °C ~ 55 °C |
| Maximum working pressure | 1.6 MPa |
| Pressure loss | Δp40 (≤ 40 kPa) |
| Protection class | IP68 — submersible |
| Flow sensitivity | U0/D0 — no straight pipe run required |
| Installation | Any orientation, horizontal or vertical |
| Bidirectional metering | Supported — reverse flow is measured and alarmed |
| Temperature compensation | Water temperature derived from the speed of sound; accurate across the full T30 / T50 range |
| Measuring frequency | 8 Hz, with online speed-of-sound verification |
| Event detection | Leaks (dripping) / pipe burst / reverse flow / empty pipe / low battery / strong magnetic attack |
| Environmental class | E2 / class O (outdoor installation) |
| Communication | Two configurations. Remote reading: local display plus an NB-IoT / LoRaWAN / CAT1 module, so the meter can be read on site or from the office. Local reading: the same meter and the same local display, supplied without a communication module — read on site, with optional pulse output. Only the communication differs; the measuring core and the display do not. |
| Battery | 3.6 V lithium, 15-year design life |
| Display | Local LCD — total volume, instantaneous flow, alarms. Fitted on both configurations. |
| Local interface | Optical port — no need to open the cover |
| Firmware upgrade | Local via optical port, and remote OTA |
| Data logging | Hourly / daily / monthly (≥ 24 months) |
| Quality basis | Type tested to ISO 4064:2014, Class 2, in 2026 by the Zhejiang Institute of Quality Sciences (ZJIQs), China — verified R800 range and measured pressure loss 0.038 MPa (tested model HWU15) |
Dimensions in mm. Values identical across the range are shown once, below the table. Request the dimension drawing for your model.
| Nominal Diameter | L | W | H | Centre-to-centre | Meter Thread |
|---|---|---|---|---|---|
| DN15 | 110 / 115 / 165 mm | 90.4 mm | 53.5 mm | — | G¾″ B |
| DN20 | 110 / 115 / 130 / 190 / 195 mm | 90.4 mm | 53.5 mm | — | G1″ B |
| Parameter | HWU15 | HWU20 |
|---|---|---|
| Nominal diameter (DN) | DN15 | DN20 |
| Permanent flow Q3 | 2.5 m³/h | 4.0 m³/h |
| Minimum flow Q1 | 3.125 L/h | 5 L/h |
| Weight | 0.29 kg | 0.35 kg |
We build to your specification, not to a fixed catalogue item. Tell us the market and the certification route and we will quote the configuration.
DN15: 110 / 115 / 165 mm. DN20: 110 / 115 / 130 / 190 / 195 mm. Lengths match the footprint of volumetric (piston / disc) meters, so the meter drops straight into an existing installation.
Two configurations: with a module (NB-IoT / LoRaWAN / CAT1) for remote reading, or without one for local reading with optional pulse output. Same meter, same accuracy — only the communication differs.
All-polymer as standard. A lead-free brass-body version is available where the market prefers traditional materials.
Your nameplate, model code and language on the meter and the packing.
We supply the technical documentation and sample units your local test laboratory needs to type-approve the meter under your own brand.
The measuring tube has no openings. A conventional meter is drilled and sealed to mount its sensing elements, and every one of those openings is a seal that can leak or drift. This body is one piece.
There are no moving parts, so there is nothing to wear, corrode or jam on particulates. A mechanically clean straight measuring tube lets debris pass through without affecting the reading, and an upstream strainer is not required.
The meter reads from a starting flow of 1 L/h and holds Class 2 accuracy to ISO 4064 across an R800 range, so the dripping losses that conventional meters round away are billed rather than absorbed.
Lengths are offered to match the footprint of the volumetric meters already installed in most networks, so replacement does not mean re-piping.
Type testing to ISO 4064:2014 was carried out in 2026 by the Zhejiang Institute of Quality Sciences (ZJIQs), verifying the R800 range and a measured pressure loss of 0.038 MPa on the tested model.




Standard products, OEM base meters, or a complete metering solution — send us your specification and we will work from what you actually need.